Network PA System for medium to massive jobs
Intro
The XC-9000 system is a totally electronic network PA system based on the TCP/IP protocol. By leveraging the TCP/IP protocol, the system makes certain the correct and effective transmission of all information packages. Not just can it utilize existing computer system networks, such as LANs or the Net, to send program signals, yet also it can additionally be released on a dedicated broadcasting network.
A single-server system can support up to 3000 terminals and allows for server plunging. There are no restrictions on the simultaneous broadcast networks, attaining true complete electronic broadcasting.
System Features
Flexible PA System Style
The PA system design is easy, consisting of solution monitoring software program, network microphones, network amplifiers, network audio speakers, and other devices.All tools is linked through the TCP/IP intranet procedure, enabling adaptable arrangement and very easy monitoring of the system, with complimentary control over broadcast web content, network gadgets, and regions through the network.
Comprehensive Audio Monitoring
The audio administration software consists of integrated functions for creating program plans, versatile zoning, and pre-scheduled broadcasts.It sustains 24-hour programming, enabling changing setups during all day
Versatile Sound Source Assistance
The system sustains different forms of audio resources for sending notices like live speech and BGM playback. Sound sources can originate from electronic musical applications, CD/DVD players, microphones, and so on. On top of that, the system gives diverse features of supporting numerous broadcasting features such as arranged broadcasting, zoned broadcasting, and emergency situation broadcasting.
Emergency Alarm System Assimilation
The system has an emergency alarm feature and can be integrated into a fire alarm system. When the alarm central system gets the alarming signals, the cable television will certainly transfer the signal to gadgets, which causes the XC-9000, sending out signals to speakers
Individuals can select to predetermined setups to activate full-area or zoned alarms in emergency situations. The alarm system voices come in several types and can be modified satisfying requirements. As an example, customers can change language settings, upload and edit their audio resources according to exact demands, such as intruding alarm systems, smoke alarm or air aid alarms, etc
Smoke Alarm System Integration
The system has an emergency alarm function and can be integrated into a smoke alarm system. When the alarm main unit receives the worrying signals, the wire will transmit the signal to devices, which triggers the XC-9000, sending out signals to speakers
Individuals might select to predetermined settings to turn on full-area or zoned alarm systems in emergencies. The alarm voices been available in multiple types and might be edited dealing with needs. For instance, users can transform language setups, upload and modify their audio sources according to specific demands, such as intruding alarms, smoke alarm or air aid alarm systems, and so on
Application Control for System Workflow
The system allows mobile app login and use, permitting customers to initiate broadcasts and other procedures to licensed terminals via the server software, making certain a hassle-free and streamlined experience.
Integrated SIP Compatibility
The system not only permits SIP phones to log in, however likewise can be linked to third-party SIP server or IPPBX, which develops a totally incorporated and compatible interaction system with smooth assimilation right into existing systems.
Open SDK
When huge project like clever park happens, the system supplies an open SDK integrated into third-party application systems - IP Paging Microphone
System Facilities
Main Features
Scheduled Playback
The system has the ability to automatically transmit according to the arranged tasks as long as individuals upload the audio declare each time period of the day to the web server and create a playback timetable.
Zone Broadcasting
The system can arbitrarily separate a few network tools into different areas to play defined audio programs or send out news to any type of marked area. The volume of each tool can be from another location changed.
Real-time Broadcasting
The system Web Site can transmit and record radio programs or various other outside audio resources in real-time, and at the same time transmitted them in sync.
Smoke Alarm Integration
The system can be incorporated with the fire alarm system for control. When a fire alarm signal is activated, it instantly activates the emergency program feature and sustains adjacent floor alarms. It additionally permits hand-operated emergency situation broadcasting by clicking a solitary button.
SIP Phone Combination
The system can be incorporated with SIP web servers, permitting live speech of voice broadcasting by means of SIP phones to send out news anytime and anywhere.
CCTV Integration
The digital tools such as IP POE Speakers takes on the global conventional ONVIF protocol, which enables their voices to be transmitted through VMS systems. The terminals can also be integrated with CCTV systems for synchronized broadcast.
Main Products
Audio Administration Software Program XC-9000
B/S design, supports cross-platform applications.
Covers standard broadcasting system works, enabling dividing monitoring.
Unified monitoring of terminals within the system, checking out job standing, and set quantity modification, etc.
Supports structure multi-level server architectures, deploying management according to user geographical areas.
Supplies SDK advancement plans for second advancement and integration with other system platforms.
Network Paging Console XC-9038N
Power: DC12V/1.5 A.
Show: 4-inch touchscreen, resolution 480 * 480.
Interaction Procedures: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 80dB.
Frequency Feedback: 100Hz~ 16KHz.
Running Temperature: 0~ 45 ℃.
Dimensions: 144 * 144 * 34.1 mm.
Network Paging Console XC-9037N
Power Supply: DC12V/1.5 A.
Present: 4-inch touchscreen, resolution 480 * 480.
Interaction Methods: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 80dB.
Frequency Reaction: 100Hz~ 16KHz.
Running Temperature level: 0~ 45 ℃.
Dimensions: 144 * 144 * 34.1 mm.
Network Horn Speaker GEN-6391A03
Power Supply: DC24V/2.7 A or POE.
Interaction Procedure: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Ratio: > 80dB.
Regularity Action: 100Hz~ 18KHz.
Intercom: Sustained, Integrated Microphone.
Running Temperature: -20~ 50 ℃.
Dimensions: 283.1 * 224.3 * 269mm.
Network Ceiling Speaker GEN-6211A03
Power Supply: DC 24V/1A or POE.
Interaction Procedures: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Ratio: > 80dB.
Regularity Reaction: 100Hz~ 18KHz.
Operating Temperature: -20 to 50 ° C.
Capacities: φ213 x 165mm.
Network Wall Mount Audio Speaker GEN-6011A03
Power Supply: DC24V/1A or POE.
Communication Method: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Proportion: > 80dB.
Frequency Response: 100Hz~ 18KHz.
Running Temperature: -20~ 50 ℃.
Measurements: 193x151.5 x292mm.
Network Column Speaker GEN-6191A03
Power Supply: DC24V/1A or POE.
Interaction Procedure: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 90dB.
Regularity Reaction: 45Hz~ 18KHz.
Running Temperature level: -10~ 55 ℃.
Measurements: 296x140x130mm.
Network Sound Bridge GEN-3101A01
Power Supply: POE.
Communication Protocol: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 85dB.
Regularity Response: 50Hz~ 20KHz.
Running Temperature level: -10~ 55 ℃.
Dimensions: 126x66x27mm.
Network Digital Amplifier XC-9508P
Power Supply: AC100V~ 240V, 50/60Hz.
Power: 130W, 260W, 360W, 500W.
Interaction Protocol: TCP/IP, UDP, Get More Information SIP.
Signal-to-Noise Proportion: > 80dB.
Regularity Reaction: 60Hz~ 18KHz.
Running Temperature: -10~ 50 ℃.
Measurements: 440x300x44mm.
Area Mixing Digital Amplifier NBS-2301
Power Supply : A/C 220V, 50Hz.
Power : 130W , 260W , 360W , 550W , 700W.
Interaction Method : HTTP, TCP/IP, UDP, ARP, ICMP, IGMP.
Signal-to-Noise Ratio :.
Mic Input 01: ≥ 65dB,.
Mic Input 02/03: ≥ 80dB,.
Aux Input 01/02: ≥ 82dB.
Frequency Action :.
Mic Input 01: 80Hz~ 14kHz.
Mic Input 02/03: 60Hz~ 16kHz.
Aux Input 01/02: 60Hz~ 16kHz.
Running Temperature :.
10 ℃~ +50 ℃ (14 ℉~ 122 ℉)
Dimensions : 483x430x88mm.
IP User Interface Unit NAC-5003
Power Supply: AC100V~ 240V, 50/60Hz.
Communication Method: TCP/IP, UDP.
Interfaces: 1 Ethernet port, 32 alarm inputs, 8 alarm system outputs.
Operating Temperature: -10~ 50 ℃.
Measurements: 483x259x44mm.
Remedy For Institution
Flexible Zoning Broadcast:
The fully network terminals can realize flexible zoning alternatives, permitting broadcasting notifications to individual terminals or various areas ( gadgets).
Institution Bell System:
It provides college bell system at the beginning/ending of the course - SPON Communications. Numerous situations can be developed, consisting of various scheduled program jobs according to summer/winter timetable
Smoke Alarm Combination
It supports integration with emergency alarm systems, permitting fire alarm signals to be incorporated into the PA system.
Classroom Audio Boosting
Terminals sustain everyday applications in classroom scenes. They can be connected to projectors or interactive white boards for audio amplification.
Smart Road Lamp/Security Pole
Support SIP Protocol:
Integrated SIP procedure for smooth integration with network interaction systems.
VMS Platforms Integration:
Integrated ONVIF method for combination with VMS systems.
Third-Party Combination:
Built in HTTP API for combination with 3rd party systems.
Voice Alarm Causing:
Built in alarm system input user interface for setting off voice alarm systems with cams.
Solution For Resort
Zone Control by Flooring:
The system provides complete network setups, splitting areas depending on different floors and control over each area separately.
Emergency Alarm Integration:
The system can be incorporated with emergency alarm system, making it possible for combination of emergency alarm signals into the broadcasting system.
Scheduled Broadcasting:
It supports programmable arranged broadcasting, permitting adaptable plans according to different needs.
Emergency Broadcasting:
It sustains emergency situation broadcasting for the entire area, making it possible for one-click emergency situation communication.
Remedy For Factory
Zone Broadcasting:
It enables relaying to any kind of area, assuring no interference between different areas.
Alarm system Triggering:
Terminals have different kinds of user interfaces, making it possible for to trigger alarms when connected with cams.
All Network Devices:
Implementation of completely network tools substantially lowers the trouble of running such as checking tools on dangerous sites, and thus safeguarding people and property.
The deployment of blog all network tools greatly decreases the problem of operation and upkeep monitoring
Integrated SIP Phones:
The system can be incorporated with SIP phone and broadcast notices using SIP phones at any time and anywhere. Two-way audio talkback in between SIP phones and IP POE Audio speakers makes it very easy for checking gadgets sitting in office or other workplaces.
The XC-9000 system is a completely digital network PA system based on the TCP/IP method. By leveraging the TCP/IP procedure, the system makes sure the right and effective transmission of all information packets. The system supports numerous types of audio resources for sending notices like live speech and BGM playback. In addition, the system provides diverse features of supporting various broadcasting attributes such as arranged broadcasting, zoned broadcasting, and emergency situation broadcasting.
The system can be incorporated with the fire alarm system for control.
Report this page